120V/20A, 2U Programmable Sequencer Surge Eliminator & Power Conditioner
Model: SEQ
- Magnetic shielding steel enclosure
- 9ft grounded 3-wire #12 line cord
- Three sequenced banks of four receptacles with combined load of 20 amperes
- Two receptacles always on
- Control output for fourth external bank
- Magnetic shielding steel enclosure
- 9ft grounded 3-wire #12 line cord
- Three sequenced banks of four receptacles with combined load of 20 amperes
- Two receptacles always on
- Control output for fourth external bank
- Can be used to control other SurgeX surge eliminators and power conditioners, or daisy-chained with other SEQs
- Easy setup and programming
- LCD display
- Setup stored in nonvolatile memory
- Provides continual display of AC line voltage
- Accommodates any type of control input
- DC voltage or contact closure feedback to
- Crestron, AMX or similar control devices.
- Output to drive up to four status LEDs
- Advanced Series Mode surge protection
- COUVS catastrophic over/under-voltage shutdown
- SurgeX ICE inrush current elimination technology
- Advanced Impedance Tolerant EMI/RFI filtering
- Thermal circuit breaker overload protection
- 10-year warranty
- Made in USA
- Warranty - Yes
- UL Rated - Yes
- Spec Sheet available - Yes
- Operating Temperature (Maximum): 95 F
- Operating Temperature (Minimum): 41 F
- Cord Length (in/mm): 108 in
- Current Rating: 20 Amps
- Number of Outlets: 12
- UL Rated: Yes
- AC Voltage: 120 Volts
- Current Draw: 20 Amps
- Depth: 10.50 in
- Height: 3.50 in
- Width: 19 in
- Product Weight: 16 lbs
- Warranty (Length/Type): 10 Year
- Power Requirement (no load): 20 Watts
- UL 1449 Adjunct Classification Test Results: 1000 surges, 6000 volts, 3000 amps, B3 pulse, measured suppressed voltage 170 volts, no failures
- Federal Guidelines: Grade A, Class 1, Mode 1 (CID A-A-55818)
- EMI/RFI Filter, Normal Mode (50-ohm load): 40 dB @ 100 kHz; 50 dB @ 300 kHz; 50 dB @ 3 MHz; 50 dB @ 30 MHz:
- EMI/RFI Filter, Common Mode (50-ohm load): 18 dB @ 300 kHz; 30 dB @ 1 MHz; 50 dB @ 5 MHz; 50 dB @ 20 MHz:
- Endurance (C62.41-1991 Category B3 pulses): 1 kV>500,000; 3 kV>10,000; 6 kV>1000:
- Control Inputs: Momentary Switch, Latching Switch, Contact Closure or 5-30 Vdc
- Input Control Current: 3 mA
- DC Voltage Output: 12 Vdc, 40 mA maximum load
- Auxiliary Relay Output: 1 amp, 30 Vdc
- Delay Times: 0 to 40 seconds
- Humidity Range: 5% to 95% R.H non-condensing
- Agency Listings: ETL and cETL (UL 1449, 2nd edition; CSA C22.2 No.8-M1986, R2000)