PRO AV CATALOG
SmartOnline 208/240 & 120V 16kVA 11.2kW Double-Conversion UPS, 8U, Extended Run, Network Card Slot, USB, DB9, Bypass, Hardwire
Series: SMARTONLINE™
Model: SU16000RT4UHW
- True on-line, double-conversion UPS provides pure, full-time sine wave AC output free of surges, voltage fluctuations and line noise
- 16,000VA/11,200W output power capacity with dual voltage output of 208/120V or 240/120V
- 4U high power density power module and 4U external battery pack support rackmount installation in 8 rack spaces (8U)
- Dual conversion UPS actively converts raw input from AC to DC, then back to perfect sine wave AC output with enhanced protection from harmonic distortion, fast electrical impulses and other hard-to-solve power problems not addressed by other UPS types
- Hardwire input and output terminals are mounted on a detachable backplate with manual bypass switch to enable hot-swappable UPS replacement without powering off connected equipment
- True on-line, double-conversion UPS provides pure, full-time sine wave AC output free of surges, voltage fluctuations and line noise
- 16,000VA/11,200W output power capacity with dual voltage output of 208/120V or 240/120V
- 4U high power density power module and 4U external battery pack support rackmount installation in 8 rack spaces (8U)
- Dual conversion UPS actively converts raw input from AC to DC, then back to perfect sine wave AC output with enhanced protection from harmonic distortion, fast electrical impulses and other hard-to-solve power problems not addressed by other UPS types
- Hardwire input and output terminals are mounted on a detachable backplate with manual bypass switch to enable hot-swappable UPS replacement without powering off connected equipment
- Provides perfectly regulated, sine wave output power free of line noise, transient surges and frequency variation for the most efficient operation of critical servers, networking and telecommunications equipment
- Maintains output within 3% of selected 208/120V or 240/120V nominal voltage during brownouts and overvoltages
- Supports connected equipment during blackouts for 12/5 min. at half/full load levels; runtime is further expandable with optional external battery packs (Model BP192V18-4U)
- Some external battery configurations require the use of Tripp Lite's External Battery Configuration Software (see manual)
- Network interfaces support simultaneous communications via DB9 port, USB port and SNMPWEBCARD slot. DB9 port supports RS-232 and dry contact messaging. HID-compliant USB interface enables integration with built-in power management and auto shutdown feature
- Included PowerAlert UPS monitoring software supports safe unattended shutdown, monitoring and control via local connected servers, plus any number of additional servers over IP
- Communications ports support on-battery, low-battery, power-restored, AC-voltage, DC-voltage, output current monitoring, battery charge current, battery capacity, AC line frequency, timed inverter shutoff, activate self-test and output power control
- Built-in Emergency Power Off (EPO) interface with cable
- Supports hardwire output at 208V and 120V
- Split phase, four-conductor hardwire input connection on included detachable PDU
- Front panel LEDs and LCD readout with scroll button enables visual confirmation of all major UPS functions and current site electrical conditions
- Front panel switches enable power on/off control, self-test and alarm cancel functions
- Included adjustable mounting rails support installation in 4-post 19-in. rack enclosures
- Optional 2-9USTAND tower stand set supports upright tower installation
- Optional 2POSTRMKITWM accessory enables 2-post rackmount installation
- Fault tolerant electronic bypass maintains utility output during a variety of UPS fault conditions
- $250,000 Ultimate Lifetime Insurance (USA and Canada Only)
- Package Includes SU16000RT4UHW UPS Power Module, BP192V18-4U External battery pack, SUPDMB16KHW Detachable PDU with manual bypass switch, 4-post rackmount installation brackets
- Warranty - Yes
- Rackmountable - Yes
- Spec Sheet available - Yes
- Operating Temperature (Maximum): 104 F
- Operating Temperature (Minimum): 32 F
- Active Power: 11200 Watt
- DC Voltage: 192 Volts
- Depth: 40.50 in
- Height: 7 in
- Width: 17.50 in
- Product Weight: 239 lbs
- Shipping Weight: 448.80 lbs
- Warranty (Length/Type): 2 Years
- Rack Units (Height): 8U
- Output volt amp capacity: 16000 VA
- Output power factor: 0.7
- Output Capacity Details: 16,000 VA (240V) / 13,860 VA (208V) / 11,200 watts (208/240V)
- Crest Factor: 3:1
- Nominal Output Voltage(s) Supported: 120V; 208V; 240V
- Nominal Voltage details: 240/120V or 208/120V split phase output
- Frequency Compatibility: 60 Hz
- Output voltage regulation (line mode): +/- 3%
- Output voltage regulation (Economy line mode): +/- 10%
- Output voltage regulation (Battery mode): +/- 3%
- Built-in UPS output receptacles: Hardwire
- Output AC waveform (AC mode): Sine wave
- Output AC waveform (battery mode): Pure Sine wave
- Rated input current (at maximum load): 68 A
- Nominal Input Voltage(s) Supported: 208V AC / 120V AC (4 wire split single phase); 240V AC /120V AC (4 wire split single phase)
- UPS input connection type: Hardwire
- UPS input connection description: 4 wire split-phase input (L1, L2, N, G)
- Recommended Electrical Service: 70A 208/240-120 Split Phase
- Full load runtime (minutes): 5 min. (11,200w)
- Half load runtime (minutes): 12 min. (5600w)
- Battery recharge rate (included batteries): Less than 6 hours from 10% to 80%
- UPS AC suppression response time: Instantaneous
- nstalled whole system maximum rack depth: 40.5 inch
- Included battery pack dimensions (height x width x depth): 7 x 17.5 x 27.8 inch
- Included battery pack weight: 239 lbs
- UPS Shipping dimensions (height x width x depth): 45.5 x 23.5 x 34.3 inch
- UPS housing material: Steel
- Cooling Method: Fan
- Storage Temperature Range: -15 to +50 °C
- Relative Humidity: 0 to 95%, non-condensing
- AC mode BTU / hr. (full load): 5690.1
- Battery mode BTU / hr. (full load): 4231.1
- Audible Noise: 60 dBA at front side 1 meter
- Low voltage transfer to battery power (setpoint): 65 V (L1-N:L2-N)
- High voltage transfer to battery power (setpoint): 140 V (L1-N:L2-N)
- UPS Certifications: Tested to UL1778 (USA); Tested to CSA (Canada); Tested to NOM (Mexico); Meets FCC Part 15 Category A (EMI)
- RoHS: Yes
- CISCO: Yes
- Rackmountable: Yes
External 192V 4U Rack/Tower Battery Pack for select Tripp Lite UPS Systems (BP192V18-4U)
Suggested Products
Advanced Sound & Communication
3817 Broadway
Kansas City, MO 64111
USA
(816) 931-9525
www.advancedsoundkc.com